Difference between revisions of "S-61R Pelican"

From
Jump to: navigation, search
(Replacable Components)
(Replacable Components)
Line 140: Line 140:
 
|#1 Generator
 
|#1 Generator
 
|20
 
|20
 +
|
 +
* #1 GEN light
 +
* Fuel gauges will read 0 if both generators are failed.
 +
|
 +
n/a
 
|-
 
|-
 
|#2 Generator
 
|#2 Generator
 
|20
 
|20
 +
|
 +
* #2 GEN light
 +
* Fuel gauges will read 0 if both generators are failed.
 +
|
 +
n/a
 
|-
 
|-
 
|#1 Eng. Fuel Filter
 
|#1 Eng. Fuel Filter
Line 165: Line 175:
 
|20
 
|20
 
|-
 
|-
|Auxilary Hydraulic
+
|Auxiliary Hydraulic
 
|20
 
|20
 
|-
 
|-

Revision as of 22:27, 3 June 2020

S-61R/CH-3C/E
HH-3E Jolly Green Giant
HH-3F "Pelican"
Lua error: Cannot create process: proc_open(/dev/null): failed to open stream: Operation not permitted
US Coast Guard HH-3F "Pelican" from Coast Guard Air Station San Francisco

The S-61R ...

1 General

2 Systems

3 Tables

4 Fluids

5 Avionics

6 Limits

7 Weight and Balance

8 Normal Procedures

9 Emergency Procedures

10 Servicing

11 SL Features

Fluid Capacity Burn Rate Description
Engine #1 Oil 10 qt. 0.7 qt/hr. When oil level falls below 50%, engine damage (chip) becomes possible. (Manual says low level is 25%)
Engine #2 Oil 10 qt. 0.7 qt/hr. When oil level falls below 50%, engine damage (chip) becomes possible. (Manual says low level is 25%)
Main Transmission 44 qt. /hr. When oil level falls below 50%, transmission damage (chip) becomes possible.
Intermediate Gear box 0.8 qt. /hr. When oil level falls below 50%, transmission damage (chip) becomes possible.
T/R Transmission 1.6 qt. /hr. When oil level falls below 50%, transmission damage (chip) becomes possible.
Primary Servo Hydraulic 1.8 qt. %/hr. When level falls below 10%, no hydraulic pressure is produced.
Auxiliary Servo Hydraulic 1.8 qt. /hr. When level falls below 10%, no hydraulic pressure is produced.
Utility Hydraulic 5.04 qt. /hr. When level falls below 10%, no hydraulic pressure is produced.

11.1 Replacable Components

Description Lifetime Failure Symptoms Wear Causes
#1 Engine 100
  • Zero Torque and RPM
  • Fire Indication
  • Low Fluids
  • High Torque
  • High N2
#2 Engine 100
  • Zero Torque and RPM
  • Fire Indication
  • Low Fluids
  • High Torque
  • High N2
Auxiliary Power Unit 100
  • Failure to reach 100% RPM
  • Low Fluids
Main Rotor Blades 200
  • Rotor blade fails to turn
  • Hard Landing
  • Collective /w Low RPM
Tail Rotor Blades 200
  • T/R blade fails to turn
  • Hard Landing
Main Transmission 150
  • M/R blade fails to turn

Warning Symptoms:

  • XMSN CHIP MAIN light
  • Excessive Rotor RPM
Tail Transmission 150
  • T/R fails to turn

Warning Symptoms:

  • XMSN CHIP TAIL light
  • Excessive Rotor RPM
Intermediate Transmission 150
  • T/R fails to turn

Warning Symptoms:

  • XMSN CHIP TAIL light
  • Excessive Rotor RPM
#1 Generator 20
  • #1 GEN light
  • Fuel gauges will read 0 if both generators are failed.

n/a

#2 Generator 20
  • #2 GEN light
  • Fuel gauges will read 0 if both generators are failed.

n/a

#1 Eng. Fuel Filter 20
#2 Eng. Fuel Filter 20
#1 Eng. Fire Extinguisher On Use
#2 Eng. Fire Extinguisher On Use
APU Fire Extinguisher On Use
Air Bottle On Use
Primary Hydraulic 20
Auxiliary Hydraulic 20
Utility Hydraulic 20
#1 Eng. Fuel Pump 30
#2 Eng. Fuel Pump 30
#1 Forward Boost Pump 30
#2 Forward Boost Pump 30
#1 Aft Boost Pump 30
#2 Aft Boost Pump 30
Battery 50
Landing Gear 100
Wiring Harness (AC & DC) 400
#1 Eng. Fuel Controller 75
#2 Eng. Fuel Controller 75