Difference between revisions of "Chinook CH-47/Normal Procedures"

From
Jump to: navigation, search
(Before Starting Engines)
(Before Starting Engines)
Line 70: Line 70:
 
<li> No 1 and No 2 PDPs. – Check all circuit breakers in and gang bars up.
 
<li> No 1 and No 2 PDPs. – Check all circuit breakers in and gang bars up.
 
<li> Overhead switches set as follows
 
<li> Overhead switches set as follows
 +
<ol style="list-style-type:lower-alpha">
 
<li> EXT LTG switches – as required
 
<li> EXT LTG switches – as required
 
<li> CPL LTG switches – as required
 
<li> CPL LTG switches – as required
Line 79: Line 80:
 
<li> LTG switches – as required
 
<li> LTG switches – as required
 
<li> FUEL CONT switches – as follows
 
<li> FUEL CONT switches – as follows
 +
<ol style="list-style-type:lower-alpha">
 
<li> XFEED switch - OPEN
 
<li> XFEED switch - OPEN
 
<li> REFUEL STA switch – OFF
 
<li> REFUEL STA switch – OFF
 
<li> L MAIN FUEL PUMP switches – ON
 
<li> L MAIN FUEL PUMP switches – ON
 
<li> All remaining FUEL PUMP switches - OFF
 
<li> All remaining FUEL PUMP switches - OFF
 +
</ol>
 
<li> ENG COND levers – STOP
 
<li> ENG COND levers – STOP
 
<li> FADEC switches – as follows
 
<li> FADEC switches – as follows
 +
<ol style="list-style-type:lower-alpha">
 
<li> B/U PWR switch - OFF
 
<li> B/U PWR switch - OFF
 
<li> LOAD SHARE switch – TRQ
 
<li> LOAD SHARE switch – TRQ
 
<li> 1 and 2 PRI/REV switches – PRI
 
<li> 1 and 2 PRI/REV switches – PRI
 
<li> NR% switch - 100
 
<li> NR% switch - 100
 +
</ol>
 
<li> INTR LTG switches – as required
 
<li> INTR LTG switches – as required
 
<li> PLT LTG – as required
 
<li> PLT LTG – as required
Line 94: Line 99:
 
<li> HOIST switches – OFF
 
<li> HOIST switches – OFF
 
<li> CARGO HOOK switches – as follows
 
<li> CARGO HOOK switches – as follows
 +
<ol style="list-style-type:lower-alpha">
 
<li> MSTR switch - OFF
 
<li> MSTR switch - OFF
 
<li> HOOK SEL switch – as required
 
<li> HOOK SEL switch – as required
 
<li> EMER REL switch - OFF
 
<li> EMER REL switch - OFF
 +
</ol>
 
<li> HYD switches –as follows
 
<li> HYD switches –as follows
 +
<ol style="list-style-type:lower-alpha">
 
<li> PWR XFER switches - OFF
 
<li> PWR XFER switches - OFF
 
<li> FLT CONTR switch – BOTH
 
<li> FLT CONTR switch – BOTH
 
<li> PWR STEER switch – ON
 
<li> PWR STEER switch – ON
 
<li> RAMP switch - ON
 
<li> RAMP switch - ON
 +
</ol>
 +
</ol>
 
<li> FIRE PULL handles – IN
 
<li> FIRE PULL handles – IN
 
<li> AGENT DISCH switch – Check
 
<li> AGENT DISCH switch – Check

Revision as of 20:42, 20 June 2021

1 General

This section describes the procedures necessary to safely and efficiently operate your aircraft. A basic understanding of helicopter flight techniques is assumed. Some of the items on the checklist are intended to be performed by the flight engineer. These items are marked with an (F).

2 Preflight Procedures

2.1 Exterior Checks

  1. Main Rotors - check condition
  2. Forward Pylon - check as follows (open access panel)
    1. Forward transmission - check condition
    2. Forward transmission oil level - check sight gauge
    3. #1 Flight Control Hydraulics - check condition
  3. Aft Pylon - check as follows (access on front of plyon)
    1. Combining transmission - check condition
    2. Engine #1 transmission - check condition
    3. Engine #2 transmission - check condition
    4. Combining transmission oil level - check sight gauge
    5. Engine #1 transmission oil level - check sight gauge
    6. Engine #2 transmission oil level - check sight gauge
  4. Engine #1 - check as follows (open access panel)
    1. Engine - check condition
    2. Engine Oil Level - check indicating bar near top
  5. Engine #2 - check as follows (open access panel)
    1. Engine - check condition
    2. Engine Oil Level - check indicating bar near top

2.2 Interior Checks

  1. Ramp Overhead Area Checks
    1. APU - check condition
    2. APU Generator - check condition
    3. Aft transmission - check condition
    4. #1 Generator - check condition
    5. #2 Generator - check condition
    6. #1 Flight Control Hydraulic Pump - check condition
    7. Utility Hydraulic Pump - check condition
    8. Aft transmission oil level - check sight gauge
    9. Engine Fire Agent Bottles - check condition and pressure. 500 psi minimum.
  2. BATT switch - ON
  3. Check fuel levels
  4. Check aft maintenance panel as follows
    1. Hydrualic fluid levels - check Utility, FC #1 and FC #2
    2. Ground contact lights - check L & R ON
    3. Oil pressure warning lights - check ON
    4. Ground Test Switch - ON
    5. All maintenace panel lights - check ON
    6. Ground Test Switch - OFF
  5. BATT switch - OFF

3 Start Procedures

3.1 Before Starting Engines

  1. No 1 and No 2 PDPs. – Check all circuit breakers in and gang bars up.
  2. Overhead switches set as follows
    1. EXT LTG switches – as required
    2. CPL LTG switches – as required
    3. COMPASS switch – as required
    4. TROOP WARN switches – OFF
    5. HTG switches – as required
    6. W/S WIPER switch - OFF
    7. ELEC switches – OFF
    8. LTG switches – as required
    9. FUEL CONT switches – as follows
      1. XFEED switch - OPEN
      2. REFUEL STA switch – OFF
      3. L MAIN FUEL PUMP switches – ON
      4. All remaining FUEL PUMP switches - OFF
    10. ENG COND levers – STOP
    11. FADEC switches – as follows
      1. B/U PWR switch - OFF
      2. LOAD SHARE switch – TRQ
      3. 1 and 2 PRI/REV switches – PRI
      4. NR% switch - 100
    12. INTR LTG switches – as required
    13. PLT LTG – as required
    14. ANTI-ICE switches – OFF
    15. HOIST switches – OFF
    16. CARGO HOOK switches – as follows
      1. MSTR switch - OFF
      2. HOOK SEL switch – as required
      3. EMER REL switch - OFF
    17. HYD switches –as follows
      1. PWR XFER switches - OFF
      2. FLT CONTR switch – BOTH
      3. PWR STEER switch – ON
      4. RAMP switch - ON
  3. FIRE PULL handles – IN
  4. AGENT DISCH switch – Check
  5. XMSN OIL PRESS switch – SCAN
  6. XMSN OIL TEMP switch – SCAN
  7. VGI switches – NORM
  8. CYCLIC TRIM switch – AUTO
  9. AFCS SYSTEM SEL switch – OFF
  10. Avionics equipment – OFF
  11. SWIVEL switch - LOCK

3.2 Starting Engines

3.3 Engine Ground Operation

4 Before Takeoff

5 Cruise Checks

6 Pre-Landing

7 After Landing

8 Shutdown Procedures