MD-500D/Appendices

From
< MD-500D
Revision as of 00:16, 28 November 2026 by Kelly (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

APPENDICES

1 Appendix A — Switch Summary

The following tables summarize the switches and other discrete controls in the MD-500D. The command names and numerical position values can be used with the switch chat commands and in macros and appliers as described in Section 12 — SL Features. Switch names are case-insensitive.

For switches with two positions, the s command can be used to toggle the switch, or the s0 and s1 commands can be used to explicitly select a position. For switches with three positions, the s0, s1 and s2 commands select the corresponding positions. The same numerical values are used when assigning switch positions with the PUSH command in a macro or applier.

A dash (—) in the Command Name column indicates that no direct switch command is available for that control.

1.1 Main Electrical Switch Panel

Switch Command Name Positions Function
Battery batt 0 = OFF
1 = EXT
2 = BATT
Selects the source of electrical power.
Scavenger Air scav 0 = OFF
1 = ON
Controls the engine air particle separator scavenger air system.
Pitot Heat pitot 0 = OFF
1 = ON
Controls electrical heating of the pitot tube.
Utility Power utlpwr 0 = OFF
1 = ON
Controls power to the utility electrical circuit.
Start Pump startpmp 0 = OFF
1 = ON
Controls the electrically driven fuel start pump.
Generator gen 0 = OFF
1 = ON
Enables operation of the generator.
Position Lights pos 0 = OFF
1 = ON
Controls the exterior navigation position lights.
Anti-Collision anticol 0 = OFF
1 = ON
Controls the anti-collision lights.
Auto Reignition autoReIgn 0 = OFF
1 = ON
Enables the automatic engine reignition system.

1.2 Main Circuit Breaker Panel

All circuit breakers use a position value of 0 for OUT (open) and 1 for IN (closed). Pulling a circuit breaker interrupts electrical power to its associated circuit.

Circuit Breaker Command Name Protected Circuit
GYRO brkGyro Gyroscopic instruments.
LDG LT brkLdg Landing light.
PNL LT brkPnl Instrument panel lighting.
INST brkInst Electrical instruments.
TRIM brkTrim Flight control trim system.
N2 GOV brkN2 N2 governor control system.
ENG OUT brkEng Engine-out warning system.
GEN brkGen Generator control circuit.

1.3 Auxiliary Circuit Breaker Panel

Circuit Breaker Command Name Protected Circuit
NAV/COM brkRad Navigation and communication radios.
XPDR brkXpd Transponder.
FLOATS brkFlt Emergency flotation system.
CARGO brkCrg Electrical cargo hook release system.
CIGAR brkCig Cigar lighter circuit.
START PUMP brkStrt Electrical fuel start pump.
SEARCH LT PWR brkSPwr Searchlight power circuit.
SEARCH LT CONT brkSCo Searchlight control circuit.

1.4 Flight Control Switches

Switch Command Name Positions Function
Starter starter 0 = Released
1 = Engaged
Controls operation of the engine starter. The switch retains its selected position until changed.
Landing Light ldglt 0 = OFF
1 = ON
Controls the landing light.
N2 Trim Up — Momentary Increases the N2 governor setpoint while the up arrow on the throttle overlay is held.
N2 Trim Down — Momentary Decreases the N2 governor setpoint while the down arrow on the throttle overlay is held.

1.5 Engine and Fuel System Controls

Switch Command Name Positions Function
Key Switch key 0 = OFF
1 = ON
Enables engine starting.
Fuel Cutoff fuelCutoff 0 = Normal
1 = Cutoff
Controls the fuel cutoff valve.
Filter Bypass bypass 0 = Normal
1 = Bypass
Selects normal filtered engine intake air or the filter bypass.
Auxiliary Fuel Valve auxValve 0 = CLOSED
1 = OPEN
Controls fuel flow from the auxiliary fuel tank.
Engine Anti-Ice antiIce 0 = OFF
1 = ON
Controls the engine anti-icing system.

1.6 Cabin Controls

Switch Command Name Positions Function
Air Vent airVent 0 = CLOSED
1 = OPEN
Controls cabin ventilation.
Cabin Light cabinLight 0 = WHITE
1 = OFF
2 = RED
Selects white or red cabin illumination.
Passenger Light psgrLight 0 = WHITE
1 = OFF
2 = RED
Selects white or red passenger compartment illumination.
Cabin Heat cabinHeat 0 = OFF
1 = ON
Controls the cabin heating system.

1.7 Instrument Panel Controls

Switch Command Name Positions Function
ELT elt 0 = ARM
1 = OFF
2 = ON
Selects the operating mode of the emergency locator transmitter.
CDI GPS/VOR cdi 0 = VOR
1 = GPS
Selects the navigation source displayed on the course deviation indicator.
Annunciator Light Test — Momentary Illuminates the annunciator lights to verify their operation.
Auto Reignition Reset — Momentary Resets the automatic reignition system.

1.8 Optional Equipment Controls

The following controls are associated with optional equipment and may not be present or operational on all aircraft configurations.

Switch Command Name Positions Function
Searchlight srchLt 0 = OFF
1 = ON
Controls the searchlight.
Cargo Hook Release — Momentary Operates the normal electrical cargo hook release.
Cargo Hook Emergency Release — Momentary Operates the mechanical emergency cargo hook release independently of electrical power.
Emergency Floats Test — Momentary Tests the emergency flotation system.
Emergency Floats Deploy — Momentary Deploys the emergency floats using the deployment button on the cyclic overlay.

Although the cargo hook release controls do not have direct switch command names, they can be operated using the following chat commands:

Command Function
w open
w hookopen
Operates the normal electrical cargo hook release.
w emeropen
w eopen
Operates the mechanical emergency cargo hook release.

Refer to Section 9 for additional information on the cargo hook system and Section 10 for information on the emergency flotation system.

2 Appendix B — Warning and Indicator Lights

The following tables summarize the warning and indicator lights installed in the MD-500D. Warning lights indicate abnormal operating conditions or equipment failures, while status indicators provide information concerning the operating state of aircraft systems.

Refer to Section 2 for detailed descriptions of the associated systems and Section 7 for emergency procedures.

2.1 Main Annunciator Panel

Main Annunciator Panel

The main annunciator lights are listed below in order from left to right. All warning annunciators should normally be extinguished during flight.

Indicator Color Meaning
ENGINE OUT Red Engine-out condition detected.
XMSN OIL PRESS Red Low main rotor transmission oil pressure.
XMSN OIL TEMP Red Excessive main rotor transmission oil temperature.
GEN OUT Red Generator is not supplying electrical power to the aircraft electrical system.
ENGINE CHIPS Red Metallic particles detected in the engine oil system.
M/R XMSN CHIPS Red Metallic particles detected in the main rotor transmission oil system.
T/R XMSN CHIPS Red Metallic particles detected in the tail rotor transmission oil system.
FUEL LOW Red Fuel quantity below the low-fuel warning threshold.
FUEL FILTER Red Excessive restriction of the engine fuel filter.

The PRESS TO TEST button at the right end of the annunciator panel illuminates all nine warning lights to verify lamp operation. This test does not verify operation of the individual sensors or detection circuits.

2.2 Battery Temperature Indicators

Battery Temperature Warning Lights

The battery temperature warning lights are located near the upper left corner of the main instrument panel.

Indicator Meaning
BATTERY 140°F Elevated battery temperature.
BATTERY 160°F Battery overtemperature condition.

Excessive battery temperature accelerates battery deterioration and increases the risk of battery failure and fire.

2.3 Other System Indicators

Indicator Location Meaning
FILTER CLOGGED EAPS panel Excessive restriction of airflow through the engine air particle separator.
RE-IGN ARMED Automatic reignition panel Automatic reignition system armed.
PRESS TO RESET Automatic reignition panel Automatic reignition system has been activated. Press to reset the indication.
GPS Course deviation indicator GPS selected as the navigation source for the CDI.

2.4 Optional Equipment Indicators

Indicator Location Meaning
EXT Searchlight control panel Searchlight is extended. Press the indicator to test lamp operation.