MD-500D/Servicing

From
< MD-500D
Revision as of 04:21, 21 November 2026 by Kelly (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

SECTION 8. SERVICING

1 General

This section describes the routine servicing requirements for the MD-500D helicopter, including replenishment of lubricating fluids, inspection of fluid levels, battery servicing, and refueling.

Servicing shall be performed with the aircraft parked on level ground, the engine shut down, and the rotor stopped unless otherwise specified.

2 Service Points

The MD-500D is equipped with servicing points for the engine, main rotor transmission, tail rotor transmission, fuel system, and battery.

2.1 Engine Oil

The engine oil reservoir is located in the engine compartment. The oil level shall be checked before flight and replenished as required.

Oil shall be added through the engine oil filler using the approved lubricant. Avoid overfilling.

2.2 Main Transmission Oil

The main rotor transmission is located above the fuselage, beneath the main rotor mast.

The transmission oil level shall be checked using the provided oil level indication and replenished through the transmission filler as required.

2.3 Tail Rotor Transmission Oil

The tail rotor transmission is located at the aft end of the tail boom.

The transmission oil level shall be checked and replenished with the approved transmission lubricant.

2.4 Battery

The aircraft battery provides electrical power for engine starting and operation of electrical equipment when the generator is not supplying power.

Battery condition shall be checked during servicing. A battery that fails to maintain an adequate charge shall be recharged or replaced.

3 Fluid Types

Only approved lubricants and fuels shall be used when servicing the helicopter.

System Fluid
Engine Approved turbine engine lubricating oil
Main Rotor Transmission Approved transmission lubricant
Tail Rotor Transmission Approved transmission lubricant
Fuel System Approved aviation turbine fuel

Different lubricant specifications may apply to the engine and transmission assemblies. Fluids shall not be interchanged unless specifically approved.

4 Fluid Capacities

The following capacities shall be observed when replenishing fluids.

Fluid Capacity
Engine Oil To be confirmed
Main Rotor Transmission To be confirmed
Tail Rotor Transmission To be confirmed

Fluid levels shall be checked using the applicable servicing indications. The specified maximum level shall not be exceeded.

5 Fuel

5.1 Fuel Type

The MD-500D is equipped with an Allison 250-C20B turboshaft engine designed to operate on approved aviation turbine fuels.

When refueling, care must be taken to use the correct fuel type. Contamination of the fuel system with an unapproved fuel may result in engine damage or failure.

If an incorrect fuel type is introduced, the affected fuel system shall be drained and serviced before further operation.

5.1.1 Approved Fuel Types
Usage Fuel Type Restrictions
Normal Jet A / Jet A-1 Approved turbine fuel
Normal JP-4 / JP-5 / JP-8 Subject to applicable engine specifications
Alternate / Emergency Approved aviation gasoline Subject to engine operating restrictions

Emergency operation on approved aviation gasoline is limited to six hours per engine overhaul period.

When operating on alternate or emergency fuel, the start pump shall remain on until engine shutdown.

5.1.2 Fuel Capacities

Fuel capacity depends upon the installed fuel tank configuration.

Tank Capacity
Main Fuel Tank To be confirmed for installed configuration
Auxiliary Fuel Tank, if installed To be confirmed

5.2 Gravity Refueling

Gravity refueling is accomplished through the aircraft fuel filler.

The aircraft shall be properly grounded before removing the fuel filler cap.

  1. Park helicopter on level ground.
  2. Engine - OFF.
  3. Battery switch - OFF.
  4. Ground aircraft - CONNECT.
  5. Fuel filler cap - REMOVE.
  6. Verify correct fuel type.
  7. Refuel to desired quantity.
  8. Fuel filler cap - SECURE.
  9. Ground connection - REMOVE.
  10. Fuel quantity - CHECK.

WARNING: Do not refuel with the engine running. Avoid ignition sources in the vicinity of the aircraft during fueling operations.

5.3 KellyFuel

The MD-500D may be refueled using a compatible KellyFuel dispensing system.

The aircraft must be positioned within operating range of the fuel pump, and the appropriate fuel filler must be opened before dispensing fuel.

5.3.1 Preparing Aircraft for Refueling
  1. Park aircraft within 20 meters of the fuel pump.
  2. Click the pump and select the aircraft by tail number.
  3. Select the fuel tank to be filled.
  4. Open the appropriate fuel filler cap.
  5. Attach the grounding cable to the aircraft.
  6. Connect the fuel nozzle to the filler.
5.3.2 Refueling Aircraft
  1. Verify that the aircraft is properly grounded.
  2. Select the appropriate fuel type at the pump.
  3. Enter the desired fuel quantity.
  4. Reset the pump meter.
  5. Start the fuel pump.
  6. Monitor fueling until the desired quantity is reached or the tank is full.
  7. Stop the fuel pump.
  8. Disconnect the nozzle.
  9. Secure the fuel filler cap.
  10. Disconnect the grounding cable.

CAUTION: Ensure that the correct fuel type is selected before beginning refueling. Introduction of an incorrect fuel may contaminate the tank and require draining and flushing before further operation.