MD-500D/Emergency Procedures

From
< MD-500D
Revision as of 03:15, 21 November 2026 by Kelly (talk | contribs) (→‎Engine Failure)
Jump to: navigation, search

SECTION 7. EMERGENCY PROCEDURES

1 Engine Failure

1.1 In Flight

  1. Collective – Maintain Nr 97-100%
  2. Cyclic – Best glide (53-69 KIAS)
  3. Pedals – Maintain yaw control
  4. Autorotate – To suitable landing site
  5. Flare – 70-100 feet AGL
  6. At 10-15 feet – Apply collective
  7. On Landing – Collective full down

1.2 On Takeoff

  1. Below 500 AGL – Collective down, land ahead
  2. If altitude permits – Maneuver to landing site

1.3 Air Restart

Only attempt if time, altitude and conditions allow

  1. Collective – Maintain Nr 97-100%
  2. Full Shutoff – OPEN
  3. Twist Grip – CUTOFF
  4. Starter – Engage
  5. At 15% N1 – Twist Grip to IDLE
  6. At 58-65% N1 – Twist Grip to FULL OPEN
  7. Engine – Monitor for normal operation
  8. If restart fails – do Engine Failure procedures