2.1 Exterior Checks
- Main Rotors - check condition
- Forward Pylon - check as follows (open access panel)
- Forward transmission - check condition
- Forward transmission oil level - check sight gauge
- #1 Flight Control Hydraulics - check condition
- Aft Pylon - check as follows (access on front of plyon)
- Combining transmission - check condition
- Engine #1 transmission - check condition
- Engine #2 transmission - check condition
- Combining transmission oil level - check sight gauge
- Engine #1 transmission oil level - check sight gauge
- Engine #2 transmission oil level - check sight gauge
- Engine #1 - check as follows (open access panel)
- Engine - check condition
- Engine Oil Level - check indicating bar near top
- Engine #2 - check as follows (open access panel)
- Engine - check condition
- Engine Oil Level - check indicating bar near top
2.2 Interior Checks
- Ramp Overhead Area Checks
- APU - check condition
- APU Generator - check condition
- Aft transmission - check condition
- #1 Generator - check condition
- #2 Generator - check condition
- #1 Flight Control Hydraulic Pump - check condition
- Utility Hydraulic Pump - check condition
- Aft transmission oil level - check sight gauge
- Engine Fire Agent Bottles - check condition and pressure. 500 psi minimum.
- BATT switch - ON
- Check fuel levels
- Check aft maintenance panel as follows
- Hydrualic fluid levels - check Utility, FC #1 and FC #2
- Ground contact lights - check L & R ON
- Oil pressure warning lights - check ON
- Ground Test Switch - ON
- All maintenace panel lights - check ON
- Ground Test Switch - OFF
- BATT switch - OFF
3 Start Procedures
3.1 Before Starting Engines
- No 1 and No 2 PDPs. – Check all circuit breakers in and gang bars up.
- Overhead switches set as follows
- EXT LTG switches – as required
- CPL LTG switches – as required
- COMPASS switch – as required
- TROOP WARN switches – OFF
- HTG switches – as required
- W/S WIPER switch - OFF
- ELEC switches – OFF
- LTG switches – as required
- FUEL CONT switches – as follows
- XFEED switch - OPEN
- REFUEL STA switch – OFF
- L MAIN FUEL PUMP switches – ON
- All remaining FUEL PUMP switches - OFF
- ENG COND levers – STOP
- FADEC switches – as follows
- B/U PWR switch - OFF
- LOAD SHARE switch – TRQ
- 1 and 2 PRI/REV switches – PRI
- NR% switch - 100
- INTR LTG switches – as required
- PLT LTG – as required
- ANTI-ICE switches – OFF
- HOIST switches – OFF
- CARGO HOOK switches – as follows
- MSTR switch - OFF
- HOOK SEL switch – as required
- EMER REL switch - OFF
- HYD switches –as follows
- PWR XFER switches - OFF
- FLT CONTR switch – BOTH
- PWR STEER switch – ON
- RAMP switch - ON
- FIRE PULL handles – IN
- AGENT DISCH switch – Check
- XMSN OIL PRESS switch – SCAN
- XMSN OIL TEMP switch – SCAN
- VGI switches – NORM
- CYCLIC TRIM switch – AUTO
- AFCS SYSTEM SEL switch – OFF
- Avionics equipment – OFF
- SWIVEL switch - LOCK
3.2 Starting Engines
- BATT switch – ON
- CAUTION LT TEST switch – TEST. Check that all lights and the two MASTER caution lights come on. Some lights will be on before test.
- TROOP WARN ALARM and JUMP LT – Two bells, two red and two green
- (F) Fire guard posted – APU clear to start
- APU – Start as follows
- APU switch – RUN for 3 to 5 sec.
- APU switch – START for 2 sec., then RUN
- APU ON caution light– check ON
- UTIL HYD SYS caution light – check OUT
- APU GEN switch – ON. NO 1 & 2 RECT lights – OUT. L & R FUEL PRESS caution lights OUT
- PWR XFER check
- PWR XFER switches - ON
- HYD FLIGHT CONTR caution light – OUT
- Pressures normal
- (F) MAINTENANCE PANEL – check
- GND switch – TEST, then RESET
- GROUND CONTACT lights – check ON
- Systems - Normal
- Avionics – On as desired
- CARGO HOOKS HOIST/WINCH – Check operation as required
- PARKING BRAKE – Set
- CRUISE GUIDE indicator– Check for pointer in white band when CGI TEST switch is at FWD and AFT TEST.
- FIRE DETR switches – TEST. Check fire warning lights on. FIRE DETR switch back to OFF.
- Fuel Quantity – Check
- Cyclic trim indicators – Check GND position
- AFCS SYSTEM SEL switch – Check as follows
- Select individual systems and check opposite AFCS caution light OUT
- Select BOTH and check both AFCS caution lights OUT
- AFCS SYSTEM SEL switch - OFF
- Flight Control Check
- Check free movement of all controls with FLT CONTR switch in both 1 & 2 position.
- FLT CONTR switch – BOTH
- Pedal & cyclic neutral. Collective full down.
- DECU PRESTART BIT – Perform as follows
- B/U PWR switch – ON
- Wait until ENG FAIL caution lights go out
- ENG COND levers – GND
- (F) DECUs – Check displays read 88.
- GPS – Start up and configure as required
- (F) Area – Clear for start
- First Engine – Start as follows
- ENG START switch – Select engine to be started and hold until N1 reaches 10%, then release switch.
- Engine should accelerate to ground idle (50 to 59%) within 45 seconds.
- Engine oil pressure
- Engine oil pressure – check 5 psi min.
- Second Engine – Start using same method as first engine.
- P3 bellow – check as follows
- ENG 1 FADEC PRI-REV switch – REV
- FADEC FAIL Caution – ON
- N1 – Maximum change ± 3%.
- ENG 1 FADEC PRI-REV switch – PRI
- FADEC FAIL Caution – OFF
- Repeat for ENG 2
- Transmission oil pressures – Check minimum of 7 psi.
- ENG COND levers – FLT Engine acceleration should be smooth.
- GEN 1 & 2 switches – ON
- APU GEN switch – OFF
- PWR XFER 1 & 2 switches – OFF
- APU switch OFF. Check APU ON caution light OUT
- Systems – check
- Transponder – STBY
3.3 Engine Ground Operation
- FUEL PUMP and XFEED – Check operation as follows
- All FUEL PUMP switches – OFF Check L and R FUEL PRESS caution lights ON
- L AFT MAIN FUEL PUMP switch ON. Check L and R FUEL PRESS caution lights OUT. Then switch OFF.
- Remaining MAIN FUEL PUMP switches – Check as is Step b above.
- L AFT AUX FUEL PUMP switch – ON. Check L AUX PRESS light on overhead panel comes on, then goes out. Set pump switch to OFF.
- Remaining three AUX FUEL PUMPs – Check as in Step d.
- FUEL CONT switches – Set as follows
- All FUEL PUMP switches – ON
- XFEED switch - CLOSE
- ANTI-ICE systems – Check as required
- PITOT switch ON – (F) Physically check for pitot tube port heat. Then OFF
- W/S switches ON – (F) Physically check for windshield heat Then OFF
- Flight instruments – Check as follows
- HSI compass card – Check aligned with proper compass heading.
- VGI - Check
4 Before Takeoff
- Systems – check indications
- Rotor – check as required
- Torque
- Engine
- Transmission
- Fuel
- Caution/Advisory panel
- PARKING BRAKE – as required
- AFCS SYSTEM SEL switch – as required
- CYCLIC TRIM switch – check
- SWIVEL switch – LOCK
- Transponder – As required
- (F) Crew, passenger and mission equipment - Check
5 Cruise Checks
- Fuel Consumption – Check
- MAINTANCE PANEL – Check every 30 min. of flight
6 Pre-Landing
- Systems
- Rotor
- Torque
- Transmission
- Fuel
- Caution Panel
- PARKING BRAKE – As Required
- AFCS control panel – Check as follows
- AFCS HDG and ALT switches – As required
- CYCLIC TRIM switch – as required
- AFCS selector switch – as required
- (F) Crew, passengers and mission equipment – Check