MD-500D/Emergency Procedures
SECTION 7. EMERGENCY PROCEDURES
Contents
1 Engine Failure
1.1 In Flight
- Collective – Maintain Nr 97-100%
- Cyclic – Best glide (53-69 KIAS)
- Pedals – Maintain yaw control
- Autorotate – To suitable landing site
- Flare – 70-100 feet AGL
- At 10-15 feet – Apply collective
- On Landing – Collective full down
1.2 On Takeoff
- Below 500 AGL – Collective down, land ahead
- If altitude permits – Maneuver to landing site
1.3 Air Restart
Only attempt if time, altitude and conditions allow
- Collective – Maintain Nr 97-100%
- Full Shutoff – OPEN
- Twist Grip – CUTOFF
- Starter – Engage
- At 15% N1 – Twist Grip to IDLE
- At 58-65% N1 – Twist Grip to FULL OPEN
- Engine – Monitor for normal operation
- If restart fails – do Engine Failure procedures
2 Fire
2.1 Fire – On Ground
- Twist Grip – CUTOFF
- Starter – MOTOR until TOT < 150° C
- Fuel Shutoff – CLOSE
- Electrical Power – OFF
- Evacuate – Crew and passengers
- Extinguisher – Use if needed
2.2 Fire – In Flight
- LAND IMMEDIATELY
- Twist Grip – CUTOFF after landing
- Fuel Shutoff – CLOSE
- Electrical Power – OFF
- Evacuate – Crew and passengers
2.3 Cabin Fire/Smoke
- LAND – As soon as possible
- Cabin Windows – Open
- Extinguisher – Use as need
- Evacuate – Crew and passengers