Difference between revisions of "S2-S/Normal Procedures"
(→PREFLIGHT) |
(→STARTING) |
||
Line 22: | Line 22: | ||
#Collective – full down | #Collective – full down | ||
#Throttle – idle | #Throttle – idle | ||
− | |||
#Beacon – on | #Beacon – on | ||
#Fuel Cutoff – on | #Fuel Cutoff – on | ||
− | #Switches (Bat., Gen., Fuel | + | #Rotor brake - off |
− | + | #Switches (Bat., Gen., Fuel/Feed Pumps) – on | |
#Collective – raise slightly, then lower (verify low rpm horn sounds) | #Collective – raise slightly, then lower (verify low rpm horn sounds) | ||
#Volts – verify > 9 volts | #Volts – verify > 9 volts | ||
− | # | + | #Water level – Verify 100% |
− | + | #Vent valve - Open | |
− | + | #Ignitor – on | |
− | + | #Fuel Flow – 5% | |
− | + | #Boiler fire – verify | |
− | + | #Fuel Flow - Full | |
− | + | #Boiler Temp. – monitor | |
− | # | ||
− | # | ||
− | # | ||
− | |||
− | |||
− | # | ||
− | #Fuel | ||
− | |||
− | |||
− | |||
− | # | ||
− | |||
− | |||
− | |||
− | |||
+ | At 212F Boiler Temp. | ||
+ | #Vent valve – verify steam present | ||
+ | #Wait – 1 min. | ||
+ | #Vent valve - close | ||
+ | #Monitor – Boiler Press. | ||
− | + | At 200 psi Boiler Press | |
+ | #Throttle – 5% | ||
+ | #Amps – Verify not negative | ||
− | + | At 300 psi Boiler Press | |
+ | #Fuel Flow – apprx. 25% | ||
+ | #Throttle – Increase to 2000 RPM | ||
+ | #Governor – on | ||
+ | #RPM – verify between 2700 and 2900 | ||
=== SHUT DOWN === | === SHUT DOWN === |
Revision as of 12:45, 8 April 2022
SECTION 4. NORMAL PROCEDURES
1 PREFLIGHT
A thorough pre-flight inspection is essential to the safe conduct of your flight. The following procedures are recommended:
Front
- Inspect bubble for cracks
- Inspect landing lights
- Inspect airspeed anemometer
- Inspect beacon and front nav lights
- Inspect right skids and struts
Right Side
- Inspect battery and electrical connections
- Inspect primary and auxiliary fuel pumps and fuel lines
2 STARTING
Use the following procedure for normal starts:
- Controls – neutral
- Collective – full down
- Throttle – idle
- Beacon – on
- Fuel Cutoff – on
- Rotor brake - off
- Switches (Bat., Gen., Fuel/Feed Pumps) – on
- Collective – raise slightly, then lower (verify low rpm horn sounds)
- Volts – verify > 9 volts
- Water level – Verify 100%
- Vent valve - Open
- Ignitor – on
- Fuel Flow – 5%
- Boiler fire – verify
- Fuel Flow - Full
- Boiler Temp. – monitor
At 212F Boiler Temp.
- Vent valve – verify steam present
- Wait – 1 min.
- Vent valve - close
- Monitor – Boiler Press.
At 200 psi Boiler Press
- Throttle – 5%
- Amps – Verify not negative
At 300 psi Boiler Press
- Fuel Flow – apprx. 25%
- Throttle – Increase to 2000 RPM
- Governor – on
- RPM – verify between 2700 and 2900
3 SHUT DOWN
Use the following procedure to shut down the engine:
- Controls – neutral
- Collective – full down
- Governor – off
- Throttle – decrease to 2000 RPM
- Cylinder Temp – stabilized (about 160C)
- Throttle – idle
- Mixture – cutoff
- Mags – off
- Rotor brake – on (when below 200 RPM)
- Switches (Bat., Gen., Fuel Pump) – off