#Position lights as required | #Position lights as required | ||
# #1 ENGINE START | # #1 ENGINE START | ||
− | + | ##Fireguard Posted | |
− | + | ##N1 Lever to SHUTOFF | |
− | Fireguard Posted | + | ##Press starter switch |
− | N1 Lever to SHUTOFF | + | ##Verify #1 ENG STARTER ON light illuminated |
− | Press starter switch | + | ##Verify Engine #1 N1 at least 20%. |
− | Verify #1 ENG STARTER ON light illuminated | + | ##WARNING – Do not turn IGN switches ON if N1 is below 20%. A fire or engine explosion may result. #1 ##IGN switch ON |
− | Verify Engine #1 N1 at least 20%. | + | ##Advance N1 lever to GRD IDLE |
− | WARNING – Do not turn IGN switches ON if N1 is below 20%. A fire or engine explosion may result. #1 IGN switch ON | + | ##Check ENG #1 gauges in green and #1 ENG STARTER light OUT. |
− | Advance N1 lever to GRD IDLE | + | #ROTOR ENGAGEMENT |
− | Check ENG #1 gauges in green and #1 ENG STARTER light OUT. | + | ##Outside area clear |
− | ROTOR ENGAGEMENT | + | ##ROTOR BRAKE switch to OFF. |
− | Outside area clear | + | ##Verify ROTOR BRAKE ON and ROTOR BRAKE PRESS caution lights OUT. |
− | ROTOR BRAKE switch to OFF. | + | ##Advance ENG #1 N1 levers to FULL OPEN |
− | Verify ROTOR BRAKE ON and ROTOR BRAKE PRESS caution lights OUT. | + | ##Verify FIRST STAGE SERVRO pressure advance to GREEN ARC and 1ST STAGE SERVO caution light OUT |
− | Advance ENG #1 N1 levers to FULL OPEN | + | ##Verify transmission pressure and temperature indications in GREEN ARC. |
− | Verify FIRST STAGE SERVRO pressure advance to GREEN ARC and 1ST STAGE SERVO caution light OUT | + | ##Verify #1 ENGINE RPM and ROTOR RPM in GREEN ARC. |
− | Verify transmission pressure and temperature indications in GREEN ARC. | + | # #2 ENGINE START |
− | Verify #1 ENGINE RPM and ROTOR RPM in GREEN ARC. | + | ##Fireguard Posted |
− | #2 ENGINE START | + | ##N1 Lever to SHUTOFF |
− | Fireguard Posted | + | ##Press starter switch |
− | N1 Lever to SHUTOFF | + | ##Verify #2 ENG STARTER ON light illuminated |
− | Press starter switch | + | ##Verify Engine #2 N1 at least 20%. |
− | Verify #2 ENG STARTER ON light illuminated | + | ##WARNING – Do not turn IGN switches ON if N1 is below 20%. A fire or engine explosion may result. |
− | Verify Engine #2 N1 at least 20%. | + | ## #2 IGN switch ON |
− | WARNING – Do not turn IGN switches ON if N1 is below 20%. A fire or engine explosion may result. | + | ##Advance N1 lever to GRD IDLE |
− | #2 IGN switch ON | + | ##Check ENG #2 gauges in green and #2 ENG STARTER light OUT. |
− | Advance N1 lever to GRD IDLE | + | ##Advance N1 lever to FULL OPEN |
− | Check ENG #2 gauges in green and #2 ENG STARTER light OUT. | + | ##Check 2ND STAGE SERVO light OUT |
− | Advance N1 lever to FULL OPEN | + | ##Verify #2 ENGINE RPM in GREEN ARC |
− | Check 2ND STAGE SERVO light OUT | + | #After Engine Start |
− | Verify #2 ENGINE RPM in GREEN ARC | + | ##IGN switches OFF |
− | After Engine Start | + | ##APP STOP |
− | IGN switches OFF | + | ##APP MASTER switch OFF |
− | APP STOP | + | ##ANTI-ICE switches as required |
− | APP MASTER switch OFF | ||
− | ANTI-ICE switches as required | ||
===Takeoff and Climb=== | ===Takeoff and Climb=== | ||
===Pre-Landing=== | ===Pre-Landing=== | ||
===Shutdown=== | ===Shutdown=== |
Revision as of 03:02, 4 August 2021
SECTION 4. NORMAL PROCEDURES
1 Start
- PARKING BRAKE and NOSEWHEEL LOCK set.
- MASTER SWITCH panel switches as follows
- EXT POWER as required, ON for GPU start
- INV, IGN, GEN, RECT, POD PWR, ANTI-ICE switches OFF
- LDG GEAR in JACK position
- TAIL SKID as required
- BATT switch ON – check for illumination of caution lights.
- GPU connect as required
- FUEL switches
- FWD and AFT tank switches OFF
- AUX pump switches OFF
- FUEL SHUTOFF levers OFF
- N1 levers to SHUT OFF
- Overhead panel switches set as follows:
- Light switches as required
- APP MASTER switch OFF
- Check all circuit breakers IN
- Check advisory panel lights. The following lights should be on: #1 GENERATOR, #2 GENERATOR, #1 RECTIFIER, #2 RECTIFIER, #1 FUEL PRESS, #2 FUEL PRESS, 1ST STAGE SERVO, AFCS SERVO PRESS, 2ND STAGE SERVO, CO-PILOT PITOT HEAT, HOIST OIL PRESS, PILOT PITOT HEAT, ROTOR BRAKE PRESS, 1ST STAGE TAIL ROTOR SERVO, PARKING BRAKE ON
- Caution panel TEST switch to TEST. Verify all caution lights ON.
- Caution panel TEST switch to NORMAL.
- Fireguard Posted
- APP Clear
- APP Start
- MASTER switch ON
- Check LOW PRESS light ON
- APP Start, press and hold until APP N1 at 40%.
- GEN and RECT switches ON.
- Check GENERATOR and RECTIFIER caution lights out.
- Check transmission, utility hydraulic and hoist hydraulic pressure normal.
- INV switch ON
- Generators & Inverter Check
- #1 GEN switch OFF
- Check #1 GEN caution light ON, #1 and #2 RECT lights OFF.
- #2 GEN switch OFF
- Check #2 GEN light ON, #1 and #2 RECT light OFF.
- INV switch OFF
- Check #1 and #2 RECT lights ON
- #1 GEN, #2 GEN and INV switches ON
- Check GEN and RECT lights OFF
- GPU disconnect. EXT PWR switch OFF.
- PITOT HEAT switch ON. Check caution lights OUT.
- ROTOR BRAKE switch OFF, check caution light OUT.
- ROTOR BRAKE switch ON.
- FUEL SYSTEM
- #1 ENG FUEL PUMP switches ON
- Check ENG #1 pump lights OUT, #1 and #2 FUEL PRESS lights remain ON.
- Open #1 fuel valve. #1 FUEL PRESS light OUT.
- X-FEED switch ON. #2 FUEL PRESS remains ON.
- Open #2 fuel valve. #2 FUEL PRESS light OUT.
- X-FEED switch to CLOSE. #2 FUEL PRESS light ON.
- #2 ENG FUEL PUMP switches ON. #2 FUEL PRESS light OUT.
- AUX FUEL PUMP switches OFF
- FUEL TEST IND switch to IND. Verify fuel gauges read zero.
- FUEL TEST IND switch to CONT. Verify sufficient fuel levels.
- Tail skid DOWN
- Anti-collision lights ON
- Position lights as required
- #1 ENGINE START
- Fireguard Posted
- N1 Lever to SHUTOFF
- Press starter switch
- Verify #1 ENG STARTER ON light illuminated
- Verify Engine #1 N1 at least 20%.
- WARNING – Do not turn IGN switches ON if N1 is below 20%. A fire or engine explosion may result. #1 ##IGN switch ON
- Advance N1 lever to GRD IDLE
- Check ENG #1 gauges in green and #1 ENG STARTER light OUT.
- ROTOR ENGAGEMENT
- Outside area clear
- ROTOR BRAKE switch to OFF.
- Verify ROTOR BRAKE ON and ROTOR BRAKE PRESS caution lights OUT.
- Advance ENG #1 N1 levers to FULL OPEN
- Verify FIRST STAGE SERVRO pressure advance to GREEN ARC and 1ST STAGE SERVO caution light OUT
- Verify transmission pressure and temperature indications in GREEN ARC.
- Verify #1 ENGINE RPM and ROTOR RPM in GREEN ARC.
- #2 ENGINE START
- Fireguard Posted
- N1 Lever to SHUTOFF
- Press starter switch
- Verify #2 ENG STARTER ON light illuminated
- Verify Engine #2 N1 at least 20%.
- WARNING – Do not turn IGN switches ON if N1 is below 20%. A fire or engine explosion may result.
- #2 IGN switch ON
- Advance N1 lever to GRD IDLE
- Check ENG #2 gauges in green and #2 ENG STARTER light OUT.
- Advance N1 lever to FULL OPEN
- Check 2ND STAGE SERVO light OUT
- Verify #2 ENGINE RPM in GREEN ARC
- After Engine Start
- IGN switches OFF
- APP STOP
- APP MASTER switch OFF
- ANTI-ICE switches as required