Difference between revisions of "MD-500D/Normal Procedures"
(→Pre-Landing Checks) |
(→Shutdown Procedures) |
||
| Line 122: | Line 122: | ||
=== Shutdown Procedures === | === Shutdown Procedures === | ||
| + | Engine Shutdown | ||
| + | Collective Stick - FULL DOWN | ||
| + | Twistgrip –IDLE (hold for 2 minutes) | ||
| + | Note: check for NR/N2 needle split immediately after throttle cut. | ||
| + | All unnecessary electrical equipment - OFF | ||
| + | Pedals - CENTERED | ||
| + | Twistgrip - CUTOFF | ||
| + | Engine out warning at 55% N1 - CHECK | ||
| + | Auto reignition light – ON | ||
| + | Generator switch - OFF | ||
| + | NAV/COM Switches - OFF | ||
| + | All other switches - OFF | ||
| + | BATTERY/EXTERNAL PWR switch - OFF | ||
| + | Key switch - OFF | ||
Revision as of 00:08, 21 November 2026
SECTION 4. NORMAL PROCEDURES
Contents
1 General
This section describes the procedures necessary to safely and efficiently operate your aircraft. A basic understanding of helicopter flight techniques is assumed.
1.1 Preflight Procedures
1.2 Normal Startup
Electrical Power - OFF Cabin Doors - CLOSED Cyclic, collective - FULL TRAVEL Cyclic - NEUTRAL Pedals - NEUTRAL Collective - FULL DOWN Landing Light - OFF Air Filter Bypass - CHECK POSITION Vne Card - SELECT Instrument Static Position - CHECK Altimeter - SET Electrical Switches – OFF Electrical Power - ON Electrical: Battery or external power start BATTERY/EXR PWR switch: set to BATTERY for battery start; to EXT for external power start - AS REQUIRED If used, connect GPU Lights - AS REQUIRED Key switch - ON
Engine Out Warning System/Auto Reignition System Checks GEN switch ON then OFF to check audible engine out warnings Hold AUTO RE-IGN TEST switch in the TEST position. Verify the RE-IGN and ARMED lights illuminate, and the sound of the engine ignitor firing is heard. Release the AUTO RE-IGN TEST switch. Press the RE-IGN light to reset (extinguish) light. Fuel gauge - CHECK All other instruments - CHECK XMSN OIL PRESS, ENGINE OUT and GEN warning lights - CHECK ON Press-to-test caution/warning lights - CHECK Throttle twist grip to FULL OPEN, then return to CUTOFF - CHECK
Pre- Start Cyclic centered - RECHECK Collective full down - RECHECK Twistgrip in CUTOFF position - RECHECK Generator switch OFF - RECHECK Start pump - AS REQUIRED NOTE: Start pump required when using alternate of emergency fuel Rotors - CLEARED
CAUTION: During starts, overtemps above 810C for 10 sec. or less with a momentary peak at 927C for not more than 1 sec. are permitted. Consult Operation and Maint. Manual if these limits are exceeded.
ABORT START IF: TOT indicator – no immediate rise Oil Press – no indication Main rotor – not rotating by 25% N1 Ammeter – zero or positive indication
Abort start procedures Close twistgrip to CUTOFF position Use starter to continue motoring engine for at least 10 seconds or until TOT decreases below 150C
Engine Start Start/ignition button - PRESS Note: Do not motor starter more than 60 seconds without ignition occuring. Cool down 60 seconds after 1st and 2nd attempt, and 30 minutes after 3rd attempt. Rotate twistgrip to ground idle for ignition when N1 indicates 12% to 15% NOTE: Peaking of N1 below 15% may occur during cold weather starting conditions. Under these conditions, a start may be attempted at a minimum of 12% N1. GPU starts are recommended when normal cranking speed cannot be obtained by using the battery. Start button - RELEASE at 58% to 60% N1 Oil pressure 50 to 130 psi - CHECK NOTE: During cold weather operation, 150 psi oil pressure is allowable following an engine start. Remain at ground idle RPM until normal oil pressure limits are attained.
Engine Start (cont.) All caution/warning indicators out - CHECK
NOTE: Transmission oil pressure warning (XMSN OIL PRESS) will go out within 30 seconds from engine light-off
Engine idle speed - 64% to 65% N1 - CHECK All other engine instruments - CHECK N2 engine and rotor rpm indicator needles superimposed - CHECK Start pump - AS REQUIRED
Engine Run-Up Electrical Power – SELECT Select BATT Ext Power - Disconnect Generator – ON Avionics – CHECK Twist Grip – FULL OPEN Press RE-IGN – CHECK OUT N2 high beep 104% - 105% - CHECK N2 low beep 98% - CHECK Low rotor warning at 98% - CHECK RE-IGN light – CHECK ON N2 beep – SET 102% Press RE-IGN – CHECK OUT Throttle rigging check N2 102% - CHECK Twistgrip – SNAP TO IDLE If engine flameout – ABORT FLIGHT Twistgrip – FULL OPEN N2 102% - CHECK
1.3 Pre Takeoff Checks
Caution/warning lights - OUT Engine oil pressure - 90 to 130 Ammeter - CHECK READING All cabin doors – CLOSED All instruments – IN GREEN Position/anti-collision lights - AS REQUIRED SCAV AIR - AS DESIRED Takeoff Hover area and takeoff path - CLEAR N2 – 103% Height/Velocity Profile – FOLLOW
1.4 Cruise Checks
SCAV AIR - AS DESIRED
1.5 Pre-Landing Checks
Pre-Landing N2 – 103% SCAV AIR – AS DESIRED
1.6 Shutdown Procedures
Engine Shutdown Collective Stick - FULL DOWN Twistgrip –IDLE (hold for 2 minutes) Note: check for NR/N2 needle split immediately after throttle cut. All unnecessary electrical equipment - OFF Pedals - CENTERED Twistgrip - CUTOFF Engine out warning at 55% N1 - CHECK Auto reignition light – ON Generator switch - OFF NAV/COM Switches - OFF All other switches - OFF BATTERY/EXTERNAL PWR switch - OFF Key switch - OFF