Difference between revisions of "Steamly S2-S/Emergency Procedures"
(→Low Water Level) |
(→Boiler Burner Flame Out) |
||
Line 4: | Line 4: | ||
# Fuel cut-off - on | # Fuel cut-off - on | ||
+ | # Batt - on | ||
+ | # Dynamo - on | ||
# Aux fuel pump - on | # Aux fuel pump - on | ||
# Ignitor - on | # Ignitor - on |
Latest revision as of 16:06, 17 April 2022
SECTION 6. EMERGENCY PROCEDURES
1 Boiler Burner Flame Out
- Fuel cut-off - on
- Batt - on
- Dynamo - on
- Aux fuel pump - on
- Ignitor - on
- Fuel flow - 25% then as necessary
2 Low Boiler Pressure
- Collective - reduce
- Fuel Flow - increase
- Whistle - off
3 High Boiler Pressure
- Fuel flow - 5%
- Whistle - on
- Collective - increase if practical
4 Low Water Level
- Feed pump - on
- Batt - on
- Dynamo - on
If water level continues to fall
- Land - as soon as practicable