Difference between revisions of "MD-500D/Emergency Floats"
(Created page with " <span class=sa-section>SECTION 11. EMERGENCY FLOTATION SYSTEM</span> === General === The MD-500D may be equipped with an emergency flotation system designed to provide buoy...") |
|||
| Line 1: | Line 1: | ||
| − | <span class=sa-section>SECTION | + | <span class=sa-section>SECTION 10. EMERGENCY FLOTATION SYSTEM</span> |
=== General === | === General === | ||
Latest revision as of 04:59, 21 November 2026
SECTION 10. EMERGENCY FLOTATION SYSTEM
Contents
1 General
The MD-500D may be equipped with an emergency flotation system designed to provide buoyancy during emergency water landings. The system consists of inflatable floats mounted on the landing gear skids, compressed gas inflation bottles, electrically actuated inflation valves, and cockpit controls.
The floats are normally carried in a compact, stowed configuration on top of each landing skid. When deployed, the floats inflate rapidly to provide buoyancy and stability during a water landing.
The emergency flotation system is intended for emergency use only. It is not designed for routine water operations.
2 Flotation System Description
2.1 Skid-Mounted Float Assemblies
The emergency flotation system consists of two float assemblies, one mounted on each landing skid.
Each assembly contains inflatable flotation bags enclosed in a protective cover. The covers protect the folded floats from weather, contamination, and mechanical damage during normal flight operations.
When the system is activated, the inflation bags expand and emerge from their protective covers, forming flotation chambers along the landing skids.
The inflated floats provide sufficient buoyancy to support the helicopter during an emergency water landing, subject to the applicable weight and operating limitations.
2.2 Inflation Pressure Bottles
Each float assembly contains a compressed gas pressure vessel. The vessels are located within the packed float assemblies and do not require external inflation cylinders.
The pressure vessels contain compressed air or nitrogen and are connected to the flotation bags through electrically actuated inflation valves.
When the system is activated, the valves open, allowing the compressed gas to flow into the flotation bags.
The pressure vessels are single-use inflation sources and must be recharged or replaced following deployment.
2.3 Pressure Indicators
Each packed float assembly incorporates a pressure gauge visible through an inspection window.
The gauges allow the pilot to verify the inflation bottle pressure during preflight inspection without opening the float covers.
For steel pressure vessels, the normal pressure range at 70°F (21°C) is 3,000 to 3,500 PSIG.
Pressure varies with temperature. A lower indication in cold weather does not necessarily indicate loss of pressure.
| Pressure Vessel | Nominal Charge Pressure at 70°F |
|---|---|
| Steel | 3,000–3,500 PSIG |
| Composite, if installed | 3,000–3,100 PSIG |
The indicated pressure must be evaluated against the appropriate temperature correction chart for the installed pressure vessel.
CAUTION: Do not operate with pressure indications outside the permissible range for the installed flotation equipment.
2.4 Inflation Valves
Each inflation bottle is equipped with an electrically actuated valve.
Activation of the flotation system initiates the inflation sequence, releasing the stored gas into the flotation bags.
The valves are actuated by an electrical circuit controlled from the cyclic stick.
Only momentary actuation of the deployment switch is required to initiate inflation.
2.5 Float Deployment
Upon activation, both float assemblies inflate simultaneously.
The inflation sequence is automatic and requires no further pilot action after the deployment switch has been actuated.
Inflation time depends upon ambient temperature.
| Temperature | Inflation Time |
|---|---|
| 21°C (70°F) and below | Approximately 9.0 seconds |
| Above 21°C (70°F) | Approximately 6.3 seconds |
During an autorotation, sufficient altitude must be available to complete inflation before water contact.
3 Controls and Indicators
3.1 Cyclic Float Deployment Button
The emergency flotation system is activated by a recessed pushbutton located on the cyclic stick grip.
Depressing the button initiates inflation of the float assemblies.
The button is positioned to permit the pilot to deploy the floats without releasing the cyclic control.
Only momentary depression is required.
WARNING: Float deployment is irreversible in flight. Once activated, the floats remain inflated until serviced on the ground.
3.2 Float System Circuit Breaker
The FLOATS circuit breaker is located on the forward electrical panel.
The circuit breaker provides electrical protection for the flotation system activation circuit.
The breaker must be in the IN position for normal system operation.
3.3 Float System Test Button
The flotation system test button is located on the forward panel.
The test circuit permits verification of the electrical continuity of the inflation system without deploying the floats.
The system shall be tested during preflight inspection.
The test does not verify inflation bottle pressure or the mechanical condition of the flotation bags. These items must be inspected separately.
4 Operating Limitations
4.1 Maximum Inflation Airspeed
The maximum permissible airspeed for float inflation is:
| Pressure Altitude | Maximum Inflation Airspeed |
|---|---|
| Below 6,000 feet | 81 KIAS |
| 6,000 feet and above | 77 KIAS |
WARNING: Inflation above the prescribed airspeed limits is prohibited.
If an emergency occurs above the permissible inflation airspeed, reduce speed before activating the flotation system.
4.2 Flight with Floats Inflated
Flight with the floats inflated is restricted to the conditions specified by the EMERGENCY FLOATS INFLATED Vne placard.
The permissible airspeed varies with pressure altitude, temperature, and aircraft configuration.
Operation with inflated floats is limited to flight to a servicing facility for repacking and recharging the flotation system.
4.3 Gross Weight Limitations
The following limitations apply to the MD-500D with the emergency flotation system installed:
- Maximum gross weight: 3,000 pounds.
- Minimum gross weight: 1,680 pounds.
The helicopter must remain within the applicable longitudinal and lateral center-of-gravity limits.
4.4 Night Overwater Operations
Night flight over water beyond autorotational capability to land is prohibited unless the approved night landing lighting kit is installed.
4.5 Equipment Compatibility
The passenger step kit may not be installed in combination with the emergency flotation system.
5 Normal Procedures
5.1 Preflight Inspection
The flotation system shall be inspected prior to flight.
- Left float package - CHECK CONDITION AND SECURITY.
- Right float package - CHECK CONDITION AND SECURITY.
- Float covers - CHECK FOR DAMAGE.
- Left inflation bottle pressure - CHECK.
- Right inflation bottle pressure - CHECK.
- Float deployment wiring - CHECK VISIBLE CONDITION.
NOTE: Inflation bottle pressure is temperature dependent. Refer to the applicable pressure correction chart when evaluating pressure indications.
5.2 Electrical System Test
- BATTERY/EXT PWR switch - BATTERY or EXT, as applicable.
- FLOATS circuit breaker - IN.
- Float system TEST button - PRESS.
- Float test indication - CHECK.
- TEST button - RELEASE.
An unsuccessful electrical test indicates a possible fault in the inflation circuit. The system must be inspected before flight requiring emergency flotation capability.
5.3 Before Takeoff
- Float assemblies - SECURE.
- Inflation bottle pressures - CHECKED.
- FLOATS circuit breaker - IN.
- Float system electrical test - COMPLETE.
- Cyclic deployment button - CHECK ACCESSIBILITY.
5.4 Overwater Flight
During overwater operations, the pilot should remain aware of the altitude and airspeed required for successful deployment.
The flotation system should be deployed before water contact whenever a water landing becomes unavoidable.
Sufficient altitude must be available to reduce airspeed, initiate deployment, and allow the floats to inflate fully.
6 Emergency Procedures
6.1 Emergency Float Deployment
If an emergency water landing becomes necessary:
- Airspeed - REDUCE TO PERMISSIBLE INFLATION SPEED.
- FLOATS circuit breaker - CHECK IN.
- Cyclic float deployment button - PRESS MOMENTARILY.
- Float inflation - VERIFY.
- Airspeed - MAINTAIN WITHIN FLOATS-INFLATED LIMITS.
- Water landing - EXECUTE.
CAUTION: If airspeed exceeds 81 KIAS below 6,000 feet, or 77 KIAS at or above 6,000 feet, reduce speed before inflation.
Inflation should be accomplished at 2,000 feet or less above the landing surface to minimize pressure differential changes during descent.
6.2 Autorotation to Water
During an autorotation to water, the pilot must maintain rotor RPM within the prescribed power-off operating range while preparing for float deployment.
Float inflation requires sufficient altitude to complete the inflation sequence before water contact.
The following minimum deployment altitude estimates are based upon a stabilized autorotational descent rate of 1,800 feet per minute, including two seconds for pilot reaction.
| Temperature | Inflation Time | Estimated Altitude Required |
|---|---|---|
| 21°C and below | 9.0 seconds | 330 feet |
| Above 21°C | 6.3 seconds | 250 feet |
WARNING: The listed altitudes are calculated values for the stated descent conditions and are not guaranteed safe deployment altitudes under all operating conditions.
When operating near the height-velocity diagram limits, immediate pilot reaction may be required to complete float inflation before water contact.
6.3 Partial or Failed Inflation
If one or both float assemblies fail to inflate, the helicopter may have insufficient buoyancy or stability for a water landing.
- FLOATS circuit breaker - CHECK.
- Float deployment button - VERIFY ACTUATED.
- Maintain helicopter control.
- Prepare for water contact and possible rollover.
- Evacuate the aircraft as conditions permit following landing.
6.4 Water Landing
Following deployment, the pilot should maintain a controlled approach to the water surface.
Avoid excessive lateral drift, yaw, or forward speed during water contact.
After landing, the floats provide buoyancy but do not guarantee stability under all sea conditions.
Passengers should remain seated until the helicopter has stabilized and evacuation can be accomplished safely.
7 Post-Deployment Procedures
7.1 Flight with Inflated Floats
Following deployment, flight is subject to the applicable floats-inflated airspeed limitations.
Operations with inflated floats are restricted to flight to a servicing facility for repacking and recharging.
CAUTION: Tail-low landings on hard surfaces should be avoided because they may cause structural damage to the float extensions.
7.2 Float Repacking and Recharging
After deployment, the flotation system must be serviced before being returned to operational status.
Servicing includes:
- Inspection of the flotation bags and protective covers.
- Inspection of inflation valves and associated plumbing.
- Recharging or replacement of the inflation pressure vessels.
- Replacement of expended inflation actuators.
- Repacking of the flotation bags.
- Verification of pressure indications.
- Electrical continuity testing.
The floats must not be considered operational until all required servicing has been completed.
8 Inspection and Maintenance
8.1 Float Package Inspection
The flotation assemblies shall be inspected for physical damage, deterioration, and security of attachment.
Particular attention shall be given to the protective covers, inflation bags, attachment hardware, and pressure gauge inspection windows.
8.2 Pressure Bottle Servicing
Inflation pressure vessels shall be inspected and serviced according to the applicable maintenance requirements.
A pressure vessel indicating insufficient pressure must be serviced or replaced before the flotation system is returned to service.
8.3 Electrical System Inspection
The electrical deployment system shall be inspected for damaged wiring, loose connections, defective switches, and circuit breaker malfunctions.
The system test shall be performed following maintenance affecting the deployment circuit.
8.4 Float Assembly Replacement
Float assemblies that have been deployed, damaged, or found unserviceable must be repaired or replaced before further operation requiring emergency flotation capability.
Following replacement, the inflation bottle pressures and electrical deployment circuits shall be checked.