==== Power Off Landing (autorotation) ====
 +
#Autorotation – Establish at 52-69 KIAS
 +
#Landing Site - Select
 +
#Flare – 70-100 feet AGL
 +
#At 10-15 feet – Apply collective
 +
#On Landing – Collective full down
 +
 +
==== Ditching (Water Landing) – Power Off ====
 +
#Doors – Open
 +
#Autorotation – Perform
 +
#On Touchdown – Full  Collective
 +
#When Rotors Stop – Exit immediately
 +
 +
==== Ditching (Water Landing) – Power On ====
 +
#Descend to Hover
 +
#Doors – Open
 +
#Passengers - Evacuate
 +
#Hovering Auto - Perform
 +
 +
=== Electrical Malfunctions ===
 +
 +
==== Battery Hot (160F) ====
 +
#Electrical Switch – OFF
 +
#Land – As soon as possible
 +
 +
==== Battery Warning (140F) ====
 +
#Electrical Switch – OFF
 +
#Land – As soon as practicable
 +
 +
==== Generator Failure ====
 +
#GEN breaker – Check if tripped
 +
#Electrical Switch – OFF then ON
 +
#If GEN OUT remains ON
 +
##Electrical Load – Reduce
 +
##Land – As soon as practicable
 +
 +
=== Other Malfunctions ===

Revision as of 03:23, 21 November 2026

SECTION 7. EMERGENCY PROCEDURES

1 Engine Failure

1.1 In Flight

  1. Collective – Maintain Nr 97-100%
  2. Cyclic – Best glide (53-69 KIAS)
  3. Pedals – Maintain yaw control
  4. Autorotate – To suitable landing site
  5. Flare – 70-100 feet AGL
  6. At 10-15 feet – Apply collective
  7. On Landing – Collective full down

1.2 On Takeoff

  1. Below 500 AGL – Collective down, land ahead
  2. If altitude permits – Maneuver to landing site

1.3 Air Restart

Only attempt if time, altitude and conditions allow

  1. Collective – Maintain Nr 97-100%
  2. Full Shutoff – OPEN
  3. Twist Grip – CUTOFF
  4. Starter – Engage
  5. At 15% N1 – Twist Grip to IDLE
  6. At 58-65% N1 – Twist Grip to FULL OPEN
  7. Engine – Monitor for normal operation
  8. If restart fails – do Engine Failure procedures

2 Fire

2.1 Fire – On Ground

  1. Twist Grip – CUTOFF
  2. Starter – MOTOR until TOT < 150° C
  3. Fuel Shutoff – CLOSE
  4. Electrical Power – OFF
  5. Evacuate – Crew and passengers
  6. Extinguisher – Use if needed

2.2 Fire – In Flight

  1. LAND IMMEDIATELY
  2. Twist Grip – CUTOFF after landing
  3. Fuel Shutoff – CLOSE
  4. Electrical Power – OFF
  5. Evacuate – Crew and passengers

2.3 Cabin Fire/Smoke

  1. LAND – As soon as possible
  2. Cabin Windows – Open
  3. Extinguisher – Use as need
  4. Evacuate – Crew and passengers


3 Emergency Landing

3.1 Power Off Landing (autorotation)

  1. Autorotation – Establish at 52-69 KIAS
  2. Landing Site - Select
  3. Flare – 70-100 feet AGL
  4. At 10-15 feet – Apply collective
  5. On Landing – Collective full down

3.2 Ditching (Water Landing) – Power Off

  1. Doors – Open
  2. Autorotation – Perform
  3. On Touchdown – Full Collective
  4. When Rotors Stop – Exit immediately

3.3 Ditching (Water Landing) – Power On

  1. Descend to Hover
  2. Doors – Open
  3. Passengers - Evacuate
  4. Hovering Auto - Perform

4 Electrical Malfunctions

4.1 Battery Hot (160F)

  1. Electrical Switch – OFF
  2. Land – As soon as possible

4.2 Battery Warning (140F)

  1. Electrical Switch – OFF
  2. Land – As soon as practicable

4.3 Generator Failure

  1. GEN breaker – Check if tripped
  2. Electrical Switch – OFF then ON
  3. If GEN OUT remains ON
    1. Electrical Load – Reduce
    2. Land – As soon as practicable

5 Other Malfunctions