Difference between revisions of "MD-500D/Emergency Procedures"
< MD-500D
(→Engine Failure) |
(→Engine Failure) |
||
| Line 28: | Line 28: | ||
#Engine – Monitor for normal operation | #Engine – Monitor for normal operation | ||
#If restart fails – do Engine Failure procedures | #If restart fails – do Engine Failure procedures | ||
| + | |||
| + | === Fire === | ||
| + | |||
| + | ==== Fire – On Ground ==== | ||
| + | #Twist Grip – CUTOFF | ||
| + | #Starter – MOTOR until TOT < 150° C | ||
| + | #Fuel Shutoff – CLOSE | ||
| + | #Electrical Power – OFF | ||
| + | #Evacuate – Crew and passengers | ||
| + | #Extinguisher – Use if needed | ||
| + | |||
| + | ==== Fire – In Flight ==== | ||
| + | #LAND IMMEDIATELY | ||
| + | #Twist Grip – CUTOFF after landing | ||
| + | #Fuel Shutoff – CLOSE | ||
| + | #Electrical Power – OFF | ||
| + | #Evacuate – Crew and passengers | ||
| + | |||
| + | ==== Cabin Fire/Smoke ==== | ||
| + | #LAND – As soon as possible | ||
| + | #Cabin Windows – Open | ||
| + | #Extinguisher – Use as need | ||
| + | #Evacuate – Crew and passengers | ||
| + | |||
| + | |||
| + | === Emergency Landing === | ||
Revision as of 03:16, 21 November 2026
SECTION 7. EMERGENCY PROCEDURES
Contents
1 Engine Failure
1.1 In Flight
- Collective – Maintain Nr 97-100%
- Cyclic – Best glide (53-69 KIAS)
- Pedals – Maintain yaw control
- Autorotate – To suitable landing site
- Flare – 70-100 feet AGL
- At 10-15 feet – Apply collective
- On Landing – Collective full down
1.2 On Takeoff
- Below 500 AGL – Collective down, land ahead
- If altitude permits – Maneuver to landing site
1.3 Air Restart
Only attempt if time, altitude and conditions allow
- Collective – Maintain Nr 97-100%
- Full Shutoff – OPEN
- Twist Grip – CUTOFF
- Starter – Engage
- At 15% N1 – Twist Grip to IDLE
- At 58-65% N1 – Twist Grip to FULL OPEN
- Engine – Monitor for normal operation
- If restart fails – do Engine Failure procedures
2 Fire
2.1 Fire – On Ground
- Twist Grip – CUTOFF
- Starter – MOTOR until TOT < 150° C
- Fuel Shutoff – CLOSE
- Electrical Power – OFF
- Evacuate – Crew and passengers
- Extinguisher – Use if needed
2.2 Fire – In Flight
- LAND IMMEDIATELY
- Twist Grip – CUTOFF after landing
- Fuel Shutoff – CLOSE
- Electrical Power – OFF
- Evacuate – Crew and passengers
2.3 Cabin Fire/Smoke
- LAND – As soon as possible
- Cabin Windows – Open
- Extinguisher – Use as need
- Evacuate – Crew and passengers