<span class=sa-section>SECTION 6. EMERGENCY PROCEDURES</span> | <span class=sa-section>SECTION 6. EMERGENCY PROCEDURES</span> | ||
− | === | + | === Boiler Burner Flame Out === |
− | |||
− | |||
− | + | # Fuel cut-off - on | |
− | + | # Batt - on | |
+ | # Dynamo - on | ||
+ | # Aux fuel pump - on | ||
+ | # Ignitor - on | ||
+ | # Fuel flow - 25% then as necessary | ||
− | === | + | === Low Boiler Pressure === |
− | + | # Collective - reduce | |
+ | # Fuel Flow - increase | ||
+ | # Whistle - off | ||
− | + | === High Boiler Pressure === | |
− | + | # Fuel flow - 5% | |
+ | # Whistle - on | ||
+ | # Collective - increase if practical | ||
− | + | === Low Water Level === | |
− | + | # Feed pump - on | |
+ | # Batt - on | ||
+ | # Dynamo - on | ||
− | + | If water level continues to fall | |
− | + | # Land - as soon as practicable | |
− | |||
− |
Latest revision as of 16:06, 17 April 2022
SECTION 6. EMERGENCY PROCEDURES
1 Boiler Burner Flame Out
- Fuel cut-off - on
- Batt - on
- Dynamo - on
- Aux fuel pump - on
- Ignitor - on
- Fuel flow - 25% then as necessary
2 Low Boiler Pressure
- Collective - reduce
- Fuel Flow - increase
- Whistle - off
3 High Boiler Pressure
- Fuel flow - 5%
- Whistle - on
- Collective - increase if practical
4 Low Water Level
- Feed pump - on
- Batt - on
- Dynamo - on
If water level continues to fall
- Land - as soon as practicable